This meter is an insulation resistance tester with broad range of measurement which can be applied to various situations from low-voltage to high-voltage measurements. For example, measuring the insulation of high-voltage receiving station and transformer substation, as well as the electric motor and cable.
-
Ambient temp. and humidity for test: 0 – 40 °C, < 85% RH (without condensation)
• Temperature for battery charging: 10 – 40 °C, < 80% RH
• Storage temperature and humidity: -10 – 50 °C, < 90% RH (without condensation)
• Temperature and humidity for battery pack storage: -20 – 30 °C, < 80% RH (without condensation) • Operation environment: For elevation lower than 2000 m • Test method: Applying DC voltage (for measuring insulation resistance); effective value (voltage) • Display: LCD with backlight; Max. number: 999 • Overflow indication: >, OF
• Underflow indication: >, -OF
• Frequency for updating the display: For insulation resistance / leak current: once per second (once in every four seconds if AVERAGE function is used )
• Detection of output voltage: Twice per second
• Voltage: Four times per second
• Temperature: Once per second
• Graduation bar: Twice per second
• Terminals:
1. Insulation resistance / voltage test: L(+), E(-), GUARD (GUARD terminals
can only be used for insulation resistance / leak current tests).
2. Temperature sensor, USB, and charger.
• Power supply:
1. LR14 alkaline battery × 6; rated voltage: 1.5 V × 6
2. Battery pack, rechargeable nickel – metal hydride batteries; rated voltage: 7.2 V (for 500 times of charging)
• Max. power consumption:
1. 10 VA (using battery);
2. 6 VA (using rechargeable battery pack).
• Max. powering time: Alkaline battery: about 9 hours; Battery pack: about 5 hours (with 5 kV-voltage generated, with terminals in an open circuit, and with backlight turned off).
• Max. input voltage: 750 VAC, ± 1000 VDC
• Max. input frequency: 70Hz
• Max. rated voltage to earth: 1000 Vrms (CAT III), 600 Vrms (CAT IV)
• Insulation strength: 6880 VAC: 15 seconds
• Overload protection: 1000 VAC, 1200 VDC between L(+) and E(-) terminals: 1 minute
• Dimensions: About 284 mm (L)×230 mm (w)×125 mm (h)
• Net Weight: About 2.5 kg (without batteries)
• Applicable standards: The design is complied with DL/T 845.1-2004
EN61010-1:2001
• Interface: USB Ver 2.0, for communications with the PC software.
• PC application software:
1. Data transfer
2.Tester setup
3. Data output
- Broad Range of Testing Voltage:
1. Testing voltages with broad range can be generated (from 250 V to 5 KV).
2. Testing voltage can be preset as 250 V, 500 V, 1 KV, 2.5 KV, or 5 KV, or as a voltage increasing or decreasing in steps of 25 V or 100 V. - Insulation Diagnosis:
1.PI and DAR can be automatically calculated and displayed;
2.Step-voltage measurements and temperature compensation is carried out. - Large Storage Memory:
1. Up to 100 manually tested data and 10 groups of log-test data can be saved.
2. Test data can be read on LCD, or uploaded to PC - Clear Display:
1. Large-screen display. Test result is displayed with indication through a graduation bar.
2. LCD screen is backlit, which is suitable for viewing when it is dark. - PC Communication:
1. The meter is equipped with a USB interface, through which the saved test data can be uploaded to a PC for further table/figure making and report generating with convenience. - Robust and Durable:
1. With a compact structure, the tester is robust, durable and portable. - Powered by Batteries:
1. With a selection switch, the tester can be powered by an alkaline battery.
2. This tester can be continuously operated for a longer period of time than similar meters if a LR14 alkaline battery is used.
Specification | Range | Accuracy |
250V DC | 0.01MΩ~2.5GΩ | +-(5%+5) |
2.51GΩ~250GΩ | +-(10%+15) | |
500V DC | 0.01MΩ~5.0GΩ | +-(5%+5) |
5.01GΩ~500GΩ | +-(10%+10) | |
1000V DC | 0.01MΩ~10GΩ | +-(5%+5) |
10.1GΩ~500GΩ | +-(10%+10) | |
501GΩ~999GΩ | +-(15%+10) | |
2.5KV DC | 0.01MΩ~25GΩ | +-(5%+5) |
25.1GΩ~500GΩ | +-(10%+10) | |
501GΩ~999GΩ | +-(15%+30) | |
1TΩ~2.5TΩ | +-(15%+40) | |
5KV DC | 0.01MΩ~50GΩ | +-(5%+5) |
50.1GΩ~500GΩ | +-(10%+10) | |
501GΩ~999GΩ | +-(15%+20) | |
1TΩ~5TΩ | +-(20%+40) | |
10nA | 1.00nA~9.99 | +-(15%+1nA) |
100nA | 9.0nA~99.9nA | +-(15%+5) |
1000nA | 100nA~999nA | +-(2.5%+5) |
10µA | 0.9µA~9.99µA | |
100µA | 9.0µA~99.9µA | |
1000µA | 90µA~999µA | |
3mA | 0.90mA~3.00mA | |
Resistance | ||
Range of insulation | Range of humidity | Range of temperature |
0Ω~100MΩ | <85%RH | 23℃+-5℃(73℉+-9℉) |
101Ω~20GΩ | <75%RH | |
21GΩ~500GΩ | <65%RH | |
501GΩ~5TΩ | <55%RH | |
Voltage | ||
Test Mode | DC Voltage | AC Voltage |
Test Range | +-(50V~1000V) | 50V~750V(50Hz~60Hz) |
Precision error | +-(5%+5) | +-(5%+5) |
Input Resistance | Approx.10MΩ | Approx.10MΩ |
Temperature | ||
Measuing Range | Measuring Precision | |
-10℃ ~0℃ | +-1.5℃ | |
0℃ ~40℃ | +-1.0℃ | |
40℃ ~70℃ | +-1.5℃ | |
- Host computer x 1
- Tester probes leads: 3m x 3 (Red,Black,Blue)
- Crocodile clip x 3 (Red,Black,Blue)
- USB(1m) x 1
- LR14 alkaline batteries x 6
- Temprature Sensor x 1
- Data analysis Software CD x 1
- User Manual x 1
- Instrument backpack x 1
- (Optional) Rechargeable battery pack(for charging Ni-Hy battery) To be used with AC charger x 1
- (Optional) AC charger x 1